Baratron Capacitance Manometer, Unheated
- 230EA-00010AB*: 10 Torr, 1/2" Tube, 0.5% reading accuracy, 4 to 20 mA output
- 626B-29891*: 1000 Torr, 4VCR-F, 0.25% reading accuracy
- 626C13TAE9*: 1000 Torr, 1/2" Tube, 0.25% reading accuracy, 24 VDC
- 626C-33506*: 0.1 Torr, 8VCR-F, 0.25% reading accuracy, 9 pin D-Sub, horizontal calibration
- AA01A12TGCS3B00000: 100 Torr, KF25, 0.25% reading accuracy
- AA04A13TGAADT: 1000 Torr, KF16, 0.30% reading accuracy, 4 to 20 mA, 9 pin D-Sub with terminal block adapter
Baratron Capacitance Manometer, Heated 45oC
- 624H23TCECB: 2000 Torr, 8VCR-F, 0.12% reading accuracy
- 627B11TBC1B*: 10 Torr, 8VCR-F, 0.12% reading accuracy
- 627D.1MDD9B*: 1 mbar, KF16, 0.15% reading accuracy, 24 VDC, vertical calibration
- 627D01MDC9B*: 1 mbar, KF16, 0.12% reading accuracy, 24 VDC
- 627F.1MDD4B*: 0.1 mbar, KF16, 0.15% reading accuracy, 24 VDC, dual 9 pin D-Sub and Profibus, vertical calibration
- 627F01MDC9B*: 1 mbar, KF16, 0.12% reading accuracy, 24 VDC
- 627F11MDC9B*: 10 mbar, KF16, 0.12% reading accuracy, 24 VDC
- 627F11TBC1B*: 10 Torr, 8VCR-F, 0.12% reading accuracy
- 627F22TBC1B*: 200 Torr, 8VCR-F, 0.12% reading accuracy
- 629B11TDCJ1B*: 10 Torr, KF16, 0.12% reading accuracy
- AA02A13TGAS34B000000: 1000 Torr, KF16, 0.1% reading accuracy, 24 VDC
Baratron Capacitance Manometer, Heated 100oC
- 625D13TCEEU*: 1000 Torr, 8VCR-F, 0.25% reading accuracy, 15 pin D-Sub with terminal block adapter
- 628B.1TBF1B*: 0.1 Torr, 8VCR-F, 0.5% reading accuracy, vertical calibration
- 628B01TDE2B*: 1 Torr, KF16, 0.25% reading accuracy
- 628D.1MDF4B*: 0.1 mbar, KF16, 0.5% reading accuracy, 24 VDC, dual 9 pin D-Sub and Profibus, vertical calibration
- 628F01TBE1B*: 1 Torr, 8VCR-F, 0.25% reading accuracy
- 628F13MBE1B*: 1000 mbar, 8VCR-F, 0.25% reading accuracy
- 628H01TCE2B: 1 Torr, 1.33" CF Rotatable, 0.25% reading accuracy, with at temp/hrt fail indicators
- 728A11TCE2FA: 10 Torr, 8VCR-F, 0.5% reading accuracy, 9 pin D-Sub
- 728A21TCE2FB: 20 Torr, 8VCR-F, 0.5% reading accuracy, 15 pin D-Sub
- DA02A12TBAS21C00*: 100 Torr, 1/2" Tube, 0.5% reading accuracy
- E28FRETBF1B: 0.25 Torr, 8VCR-F, 0.5% reading accuracy, vertical calibration
- E28FU5TDF1B*: 0.05 Torr, KF16, 0.5% reading accuracy, vertical calibration
Baratron Capacitance Manometer, Heated 150oC
- 631C01TMFH*: 1 Torr, 1.5" Tri-Clover, 0.5% reading accuracy
- 631C02MMFH*: 2 mbar, 1.5" Tri-Clover, 0.5% reading accuracy
- 631D01MMFH*: 1 mbar, 1.5" Tri-Clover, 0.5% reading accuracy
- 631D01MNFH*: 1 mbar, 2" Tri-Clover, 0.5% reading accuracy
- 631D01TAFHBB*: 1 Torr, 1/2" Tube, 0.5% reading accuracy, with setpoint relays, activate below setpoints
- 631D02TMFH*: 2 Torr, 1.5" Tri-Clover, 0.5% reading accuracy
- 631D11T8FH*: 10 Torr, 8VCR-F, 0.5% reading accuracy
- 631D12MNFH*: 100 mbar, 2" Tri-Clover, 0.5% reading accuracy
- 631D12T8FH*: 100 Torr, 8VCR-F, 0.5% reading accuracy
- 631D12TBFH*: 100 Torr, 8VCR-F, 0.5% reading accuracy
Baratron Capacitance Manometer, Heated 200oC
- 631D11T8FP*: 10 Torr, 8VCR-F, 0.5% reading accuracy
- 631D12TBFPBB*: 100 Torr, 8VCR-F, 0.5% reading accuracy, with setpoint relays, activate below setpoints
- 631F12T8FPAB: 100 Torr, 8VCR-F, 0.5% reading accuracy, with setpoint relays, activate R1 above and R2 below setpoints